D-RX 250 Combined Probe Sensor

Brand: Durag

Certified dust monitor, combined with a flow, temperature and absolute pressure measurement for monitoring of small to medium dust concentrations in dry flue gas and process gas.
Features
  • Only one probe/installation opening in the exhaust gas channel
  • Compact design
  • No moving parts
  • Automatic zero and reference point check.

Specifications

Brand

Accuracy

  • Detection Limit: < 2 % of Measuring Range

Ambient Temperature Range

  • -20° to 50° C (-4° to 122° F)

Applications

  • Facilities for Cement Production
  • Facilities Pursuant to 27th BImschV
  • Garbage, Hazardous Waste Incinerators
  • Incineration in General
  • Installations According 2000/76/EC WID/17 BImschV, 2001/80/EC LCPD/13 BImschV/Clean Air Act, Incineration of Biomass
  • Power Stations with Gas, Oil, Coal or Co-Firing
  • Suitable for Monitoring of Filter Systems

Approvals & Certifications

  • MCERTS

Approvals & Certifications

  • CE
  • EAC
  • GOST
  • TÜV Test Report 936 / 800006 / A

Communication

  • Modbus RTU
  • RS-485

Diameter

  • Duct: 11.8 to 196.9" (300 to 5,000 mm)

Environmental Protection

  • IP65

Flow Rate

  • Insulator Purging: 2 m³/hour

Humidity

  • Flue Gas: < 80 %

Measuring Range

  • 0 to 500 mg/Nm³
  • 0 to 9,999,999 Nm³/hour
  • 0° to 200° C (32° to 392° F)
  • 0° to 350° C (32° to 662° F)
  • psi: 11.6 to 18.8 (kPa: 80 to 130, bar: 0.8 to 1.3)

Output

  • 4 x 0-20 mA / 500 ohms
  • 4 x 4-20 mA / 500 ohms

Power Supply

  • 115-230 Vac, 50/60 Hz, 50 VA

Pressure Range

  • Flue Gas: psi: -2.9 to 2.9 (kPa: -20 to 20, bar: -0.2 to 0.2)

Process Temperature

  • Flue Gas: 0° to 200° C (32° to 390° F)
  • Flue Gas: 0° to 350° C (32° to 662° F)

Relay Output

  • 0.5 A at 48 V

Supply Pressure

  • Probe Back Purging - psi: 43.5 (kPa: 300, bar: 3)

show more